The horizontal laminar flow cabinet creates a sterile work environment by directing purified air in a horizontal, unidirectional flow across the work zone, exiting uniformly across the entire open front of the cabinet. This popular product is widely used in laboratories, pharmaceutical manufacturing, and other industries. It is preferred by large laboratories and now available as the best budget option for sale at an affordable price.
Horizontal Laminar Flow Cabinet Features:
- Control panel is ergonomically positioned at the center and angled downward, easy reach and viewing.
- Work surface is made of brushed stainless steel, ensuring effortless cleaning.
- Utilizing a non-direct light source design, the cabinet effectively reduces operator visual fatigue while maintaining adequate illumination.
- The microprocessor controller features an intuitive interface with an LCD display, providing graphical and digital feedback on the operating status of each function, including filter and UV lamp life.
Horizontal Laminar Flow Cabinet Specifications:
Model |
LCB-H1100 |
LCB-H1300 |
LCB-H1600 |
LCB-H1900 |
External Size (W×D×H)(mm) |
1050×805×1950 |
1320×805×1950 |
1625x805x1950 |
1930×805×1950 |
Internal Size (W×D×H)(mm) |
950×490×574 |
1220×490×574 |
1525x490x574 |
1830×490×574 |
Control System |
Microprocessor controller with LCD display, graphical and digital display of the operating status of each function. |
Work Surface Height |
750mm |
Airflow Velocity |
Adjustable, 0.2~0.5 m/s |
HEPA Filter Efficiency |
> 99.995% at particle size at 0.3μm |
Pre-Filter |
1pcs, made of washable polyester fiber |
Sound Emission |
≤65dB(A) |
Illuminating Lamp |
LED lamp, Illumination≥900Lx |
LED Lamp |
6.5W×1 |
9.6W×1 |
9.6W×1 |
6.5W×2 |
UV Lamp |
20W×1 |
30W×1 |
30W×1 |
18W×2 |
With timing function, Interlock with front sliding sash. Emission of 253.7 nanometers for best sterilization effect. |
Power Consumption |
165W |
305W |
405W |
510W |
The power consumption does not include external device connected via power socket |
Cabinet Construction |
Main Body: Electro-galvanized steel with antimicrobial powder coating |
Work Zone: Stainless steel, grade 304 |
Manual Sliding Sash: 5 mm UV resistant tempered glass with counter-balance system and ergonomic handle |
Side Windows: 5 mm UV resistant tempered glass |
Power Supply |
AC220V ±10%, 50/60Hz,1P |
Standard Accessories |
Base stand; LED lamp; UV lamp; Waterproof socket |
Optional Accessories |
Water Tap, Gas Tap, IV bar, Height adjustable base stand |
Net Weight |
170kg |
200kg |
230kg |
165kg |
Gross Weight |
220kg |
260kg |
300kg |
340kg |
Shipping Size (W×D×H)(mm) |
1190×1010×1425 |
1460×1010×1425 |
1765×1010×1425 |
2070×1010×1425 |
Shipping Volume |
1.7m3 |
2.3m3 |
2.55m3 |
3.0m3 |
Advantages of Horizontal Laminar Flow Cabinet:
- The front sliding sash is interlocked with the fan and UV lamp for enhanced safety.
- UV sterilization includes a timing function for the UV lamp.
- Both the front sash and side windows are constructed from UV-resistant tempered glass.
- Independent capacitors are installed for the host and sockets to prevent current overload.
- A memory function ensures data retention in case of power failure.
- HEPA filter and UV life indicators ensure timely replacements.
- Two side glass windows for easy experiment observation.
- Pre-filter for extending HEPA filter’s lifetime.
- Temperature sensor displays real-time temperature.
- Waterproof socket for small instrument convenience.
Application of Horizontal Laminar Flow Cabinet:
Laminar flow cabinet is essential for creating aseptic workspaces in various environments.
They are widely used in microbiological research labs for cultivating cultures and processing samples under sterile conditions.
In pharmaceutical research and manufacturing, they ensure sterility during drug formulation, quality control, and sample handling.
Laminar flow cabinets are also crucial in clinical trials, electronics assembly, and laboratory sample preparation.
Horizontal Laminar Flow Cabinet Detail and Packing:

Clear display makes it easy to monitor the device’s operating status and parameter settings



The vertical laminar flow cabinet is fully protected and securely installed during transport. The laminar flow cabinet is surrounded by dense packing material to prevent collision and vibration during transport.
We provide sea freight, air freight, land freight, express service, accept EXW, FCA, FAS, FOB, CFR, CIF, CPT, CIP, DAF, DES, DEQ, DDU, DDP and other trade terms.
How a horizontal laminar flow cabinet works?
The vertical laminar airflow (Class 100) operates on the principle of downward airflow. Clean air enters the room through HEPA filters installed in the ceiling, then flows downwards in a laminar pattern towards the floor. Finally, the air is exhausted from the room through a grated floor system.
WHY SCITEK
- 36 Months Limited Warranty
- Help meet ISO, FDA, CE quality assurance guidelines
- 1-2 Days Handling and 7-30 Days Shipping
Get Social